1.1 Certificates: UL-E246810; CSA-256361; CCC- 2013010304614127; Semko/CE File No. EN60947-4-1:2010;
1.2 Application: HVAC/R;
1.3 Standard: UL508;ARI 780/790
1.4 RoHS Compliance
1.5 Class 3211 04/3211 84; Class NLDX2, NLDX8;
1.6 Load: 20FLA to 120FLA Coil: 24Vac to 480Vac
SA series Definite Purpose Contactor for HVAC/R application
Description
SA | 2P | 30A | 240V | -001 | ||||
---|---|---|---|---|---|---|---|---|
HECHENG DP Contactor Model Number | ||||||||
Pole and Form:
P=Form NO 1P=1pole; 2P=2poles; 3p=3poles; 4p=4poles; 1.5P= Only for 1pole without shut K= Only for 3poles,2 form NO, 1 form NC |
||||||||
Contact Rating:
20A,25A,30A,40A,50A,60A,75A,90A,120A; |
||||||||
Coil Voltage: 50/60Hz Frequency
24V, 120V, 208-240V, 277V, 480V, 300V; |
||||||||
Customer Indentification:
001-999 optional customer sepcifics designation assigned by HECHENG to specify significant variation from the standard construction |
1.1 Certificates: UL-E246810; CSA-256361; CCC- 2013010304614127; Semko/CE File No. EN60947-4-1:2010;
1.2 Application: HVAC/R;
1.3 Standard: UL508;ARI 780/790
1.4 RoHS Compliance
1.5 Class 3211 04/3211 84; Class NLDX2, NLDX8;
Why Choose Us?
Product action reliability design
Product Highlights:
Reliable pull-in at 70%~110%Us, carrying line voltage fluctuation;
The influence of voltage fluctuation:
Considering line voltage fluctuation is an inevitable phenomenon in most application scenarios, short-term pressure loss will cause the contactor to malfunction and affect the operation of the equipment; Frequent pressure loss will cause frequent contactor release, affecting product life and equipment life.
Method to realize:
Matching calculation of suction force and reaction force curve to ensure reliable suction.
Product Highlights:
Reasonable iron core and magnetic split ring, no vibration after 75% Us is attracted;
The influence of vibration:
Affect product life and temperature rise;
Method to realize:
Through the optimized design of the short-circuit ring to ensure sufficient retention.
Design of Product Reliability
Product Highlight:
Coil protective cover design to better protect the iron core;
Damage of Unprotected:
Most of the application scenarios are dusty and the iron core is not protected, which will cause the iron core area to be gray, then affect the product performance;
Product Advantage:
Silver contact point protection treatment ensures long-term low contact resistance and connection reliability;
Influence of Unprotected:
Silver contact point are easy to vulcanize, which affects product contact resistance; no power after action;
Method to realize:
Increasing the cleaning of silver contact point and the high-temperature protection treatment process, extending the vulcanization cycle of silver contact point to make the contact resistance change slowly;
Product Advantage:
AgCdO2 silver contact point, and the uniform thickness of the silver layer ensure the electrical life;
Design of Product Practicality
Product Highlight:
Full series of standard quick-connect terminals; In addition to the quick-connect terminal, there are two options for Screw connection method, and being arbitrarily matched;
Product Highlight:
The bottom plate is installed with a porous design, and the installation size can be freely selected; Product Highlight:
3P&4P accessory auxiliary contact point has multiple combinations choice , and there are micro switch types to ensure low current reliability;
-
SA_1P-1.stp
Size: 9.00 B
Type: stp
-
SA_2P.stp
Size: 2.79 MB
Type: stp
-
SA_1P-2.stp
Size: 2.63 MB
Type: stp
-
SA_3P_3040A.stp
Size: 3.98 MB
Type: stp
-
SA_3P_5060A.stp
Size: 2.31 MB
Type: stp
-
SA_3P_7590A.stp
Size: 2.75 MB
Type: stp
-
SA_4P.stp
Size: 4.03 MB
Type: stp
1 review for SA series Definite Purpose Contactor for HVAC/R application
There are no reviews yet.